CO₂, Module Measures Four Climate Parameters
EE894
The digital module EE894 measures carbon dioxide (CO₂), relative humidity (RH), temperature (T) and ambient pressure (p). Temperature and pressure compensation ensures high CO₂ measurement accuracy under changing environmental conditions. Very small dimension and the I2C or E2 interface facilitate the design-in.
EE894 Compact – CO₂, relative humidity, temperature and ambient pressure module
EE894 Standard – CO₂, relative humidity, temperature and ambient pressure module
The dual wavelength NDIR technology with auto-calibration is particularly long-term stable and insensitive to contamination. A multiple point CO₂ and T factory adjustment leads to excellent CO₂ measurement accuracy over the entire T working range. The pressure compensation minimizes the impact of altitude and ambient pressure variations onto the CO₂ readings.
The measured data, with a range of up to 1% CO₂, is available on the I²C or the E2 digital interface. Small dimensions and electrical connection via contact pins, edge card socket or pads facilitate the design-in.
An optional kit for the E2 interface facilitates easy configuration of the module and the adjustment of the CO₂, RH, T and p measurement. The CO₂ measurement interval can be set according to the application requirements; by this the average current consumption can be reduced to 420 μA, ideal for battery-operated devices.
Typical Applications
- Demand controlled ventilation
- Building automation
- Data loggers and hand helds
- Wireless transmitters
Key Features
- Dual wavelength NDIR CO₂ working principle
- Measuring range up to 10,000ppm
- Auto-calibration for excellent long term stability
- Temperature and pressure compensation
- High insensitivity to pollution
- Easy user configuration and adjustment
- Very low current consumption
- Miniature size
Technical Data
Measuring Range CO₂ 0...2000 ppm 0...5000 ppm 0...10000 ppm | Accuracy CO₂ at 25 °C (77 °F) and 1013 mbar (14.69 psi) ± (50 ppm + 2 % mv*) ± (50 ppm + 3 % mv*) ± (100 ppm + 5 % mv*) |
Measuring range Relative Humidity 0…95 % RH (non condensing) | Accuracy Relative Humidity at 25 °C (77 °C) and 20...80% RH typ. ± 3 % RH |
Measuring range Pressure 700…1100 mbar (10.15...15.95 psi) | Accuracy Pressure at 25 °C (77 °C) and 20...80% RH typ. ± 2 mbar |
Measuring range Temperature -40…60 °C (-40...140 °F) | Accuracy Temperature at 25 °C (77 °F) typ. ± 0.5 °C (± 0.9 °F) |
Digital interface I²C or UART | Supply 4.75 - 7.5V DC |
Downloads EE894
Support literature
EU Declaration of Conformity